Front Panel Controls Overview
Input Control: Here the user is able to adjust the amount of input level sent into
the M76’s internal circuitry. The input level attenuator determines how much of
the signal is over the threshold and therefore compressed.
Output Control: The output control allows the user adjust the amount of level that
is being sent to the output section and output transformer. This is post compression
and only affects the output level of the M76. The user can also choose to drive the
transformer and output section.
Zero Adjust: Between the Input and Output control is a small hole. Using a small
flat blade screw driver the user can adjust the Gain Reduction Zero point. The M76
is a sensitive device and generally will require that the meter be zeroed once the
device is settled in the rack after unpacking. While VU meters are not completely
accurate they do provide a good general reference and occasional will need to be
calibrated.
Attack Control: The attack control is completely variable and allows for attack
times of: 20uSec - 800uSec.
Release Control: The release control is completely variable and offers release
times of 50 mili Sec - 1.1 Sec’s.
Link Switch: (See Linking)
Note one unit must be set internally to Slave and the other to Master for the link to
be active. If you bought a Stereo Pair they should already be set accordingly.